46-50 L ldryng Dry flux at non- T if non-gridded

gridded receptors receptors used

51-55 L lsavef Save wet/dry fluxes T (allows for postprocessing)

56-60 L lprflx Print wet/dry fluxes F (can create

voluminous output)

61-65 I ires Save results for 0=no, 1=yes

restart? Generally 1

66-70 I iint Save results every 9999 saves only last

'iint' hours and the hour for restart

last hour of the run

Card Group 7

Columns Typ Variable Description Recommended Value *

Name

1 IAE iopts(1) Use default dispersion 0

parameters (a , b , a , y y z

b , a as defined by z zt

Turner and Heffter,

T =10000, jsup=5 m

(T reset in code from m

original default value

of 100000)

2 IAE iopts(2) Use default vertical 0

diffusivity constants

k =0.01, k =0.10 1 2

3 IAE iopts(3) Use default SO canopy 0 2

resistance

4 IAE iopts(4) Use default dry 0

deposition parameters

5 IAE iopts(5) Use default wet 0

removal parameters

6 IAE iopts(6) Use default chemical 0

transformation methods

Card Groups 8-13 - NEW VALUES TO REPLACE DEFAULT PARAMETERS

The default options are recommended for all regulatory uses of the

MESOPUFF-II modeling system. If the defaults are used, these card groups

do not need to be included. See the user's manual for further

 

 

 

n1301 - n1302 - n1303 - n1304 - n1305 - n1306 - n1307 - n1308 - n1309 - n1310 - n1311 - n1312 - n1313 - n1314 - n1315 - n1316 - n1317 - n1318 - n1319 - n1320 - n1321 - n1322 - n1323 - n1324 - n1325 - n1326 - n1327 - n1328 - n1329 - n1330 - n1331 - n1332 - n1333 - n1334 - n1335 - n1336 - n1337 - n1338 - n1339 - n1340 - n1341 - n1342 - n1343 - n1344 - n1345 - n1346 - n13247 - n1348 - n1349 - n1350

 

   Flag of Portugal 

 english:

 castellano: DISPER CUSTIC DESCAR RADIA    italiano:     

 

 français:    português:  

 

deutsch:

 

 

deutsch: DIS CUS  DES  RAD

castellano: DIS CUS DES  RAD   english: DIS CUS DES RAD  

 

 português: DIS CUS DES RAD   italiano:   DIS CUS  DES RAD

 

français:  DIS CUS DES RAD