248  No Sources Were Defined on the SO Pathway.  There must be at least one LOCATION card and one SRCPARAM card to define at least one source on the SO pathway.  Either no cards were input or there were errors on the inputs.

 

250  Duplicate XPNT/DIST or YPNT/DIR Specified for GRID.  One of the grid inputs, either an X‑coordinate, Y‑coordinate, polar distance range or polar direction, has been specified more than once for the same grid of receptors. This generates a non‑fatal warning message.

 

252  Duplicate Receptor Network ID Specified.  A network ID for a grid of receptors (GRIDCART or GRIDPOLR keyword) has been used for more that one network.

 

255  Boundary Receptor Distances Not Defined Yet.  The user has input the BOUNDELV keyword for a particular source before any BOUNDARY keyword has been specified for that source.

 

260  Number of Emission Factors Exceeds Maximum.  The user has selected an option for variable emission rate factors that exceeds the array storage limit for emission rate factors. The array limit is controlled by the NQF PARAMETER specified in the MAIN1.INC file.  The value of NQF is provided with the message.

 

270  Number of High Values Specified Exceeds Maximum.  The user has selected a high short term value on the OU RECTABLE card that exceeds the array storage limit for high values by receptor.  The array limit is controlled by the NVAL PARAMETER specified in the MAIN1.INC file.  The value of NVAL is provided with the message.

 

280  Number of Maximum Values Specified Exceeds Maximum.  The user has selected a value for the number of overall maximum values on the OU MAXTABLE card that exceeds the array storage limit for overall maximum values.  The array limit is controlled by the NMAX PARAMETER specified in the MAIN1.INC file.  The value of NMAX is provided with the message.

 

285  Number of Output Types Specified Exceeds Maximum (for Short Term only).  The user has specified more than the maximum number of output types allowed (CONC, DEPOS, DDEP, and/or WDEP).  The number of output types is controlled by the NTYP PARAMETER specified in the MAIN1.INC file.  The value of NTYP is provided with the message.

 

290  Number of Events Specified Exceeds Maximum.  The user has specified more events than the ISCEV model array limits allow.  The array limit is controlled by the NEVE PARAMETER specified in the EVMAIN1.INC file.  The value of NEVE is provided with the message.

 

 

301 - 302 - 303 - 304 - 305 - 306 - 307 - 308 - 309 - 310 - 311 - 312 - 313 - 314 - 315 - 316 - 317 - 318 - 319 - 320 - 321 - 322 - 323 - 324 - 325 - 326 - 327 - 328 - 329 - 330 - 331 - 332 - 333 - 334 - 335 - 336 - 337 - 338 - 339 - 340 - 341 - 342 - 343 - 344 - 345 - 346 - 347 - 348 - 349 - 350

 

 

    Flag of Portugal 

 english:

 castellano: DISPER CUSTIC DESCAR RADIA    italiano:     

 

 français:    português:  

 

deutsch:

 

 

 

deutsch: DIS CUS  DES  RAD

castellano: DIS CUS DES  RAD   english: DIS CUS DES RAD  

 

 português: DIS CUS DES RAD   italiano:   DIS CUS  DES RAD

 

français:  DIS CUS DES RAD